High performance cold finger V2A large S-K100-Z
מספר קטלוגי : KG S-K100
Gas cleaning by condensation/vacuum systems
Made of Stainless Steel 1.4301
Made of Stainless Steel 1.4301
Manufacturer: KGW - Isotherm
DESCRIPTION
High-performance cold finger V2A large S-K100-Z
Cold Trap, two Sections
A special version is the two-section cold trap. It has an ISO-K 100 flange as the connection partThis type of cold trap enables the condensation area to be separated from the upper section of the cold trap
This ensures that the removal of the condensation and the cleaning of the cold traps can be carried out very easily
This version is also suitable for when a cold trap has to be permanently installed inside an apparatus so that only the lower section of the cold trap has to be removed in order to empty out the condensation
The ISO-K 100 flange connecting piece is secured with 4 ISO-K-claw clamp stainless steel and this is included in our scope of delivery
Applications
gas cleaning by condensation e.g in vacuum systems
versions
KF NW25 = Small flange NW25special dimensions
special connections
Advantages
baffles for optimized condensationmade of stainless steel 1.4301 (1.4404 on request)
good chemical resistance
good thermal resistance
simple low-cost design
quick exchange is possible
two sections
Cold traps / cold fingers
Hence different materials may be present in the gas stream (e.g., water/solvent/acid or alkali containing gases), the condensation temperature of the material to be condensed must be considered first. Having a cold trap, the material made off (glass or metal) and the geometry of the cold trap play an important role regarding the performance of the cold trap. In order to increase the performance of cold traps, these are sometimes provided with integrated baffles, so that the gas is more swirled in the condensation space and thus better condensation can take place on the cold inner wall of the cold trapIn general, it should be noted that the liquid used for cooling (LN2 or CO2) should be at least 50 ° C colder than the condensation temperature of the substance that you want to condensate out of the gas stream. If you would like to filter e.g. a solvent such as methanol (melting point -98 ° C) or acetone (melting point -95 ° C) out of a gas stream, you will need LN2 (about -196 ° C) as a coolant to achieve sufficient cooling capacity in the cold trap. For water, the melting point is 0 ° C which means that a mixture of CO2 and acetone (about -77 ° C) would be sufficient for water vapor
In order to obtain a constant performance of a cold trap / cold finger, the coolant level (LN2) inside the Dewar flask also must be kept constantly on a high level. This can be achieved with automatic LN2 level control. By such an automatic LN2 level controller, the cold trap / cold finger is always supplied with sufficient LN2 coolant, so that an optimal condensation performance of the cold trap / cold finger is guaranteed. For this purpose, complete LN2 level control systems for cold traps are offered
SPECIFICATIONS
Technical Data Cold finger S-K100-Z
| Type | Condensate capacity | Coolant capacity | for Dewar Type | cold finger connections | Art. No. |
|---|---|---|---|---|---|
| Cold finger S-K100-Z | app. 1,5 l | 16/18 l | 33C / DSS-D250/450 | KF NW 25 | 17154 |
Spare parts
| Spare parts | Article-No. |
|---|---|
| Dewar made of glass Type 33C | 1244 |
| Dewar made of stainless steel Type DSS-D250/450 | 2407 |
| Plastic ring for Type 33 | 17155 |
| Plastic ring for Type DSS-D250/450 | 17156 |
| CO2 wire bracket for Type 33C | 17157 |
| CO2 wire bracket for Type DSS-D250/450 | 17158 |
| Claws for S-K100-Z | 17159 |
| Centering ring ISO-K100 | 17160 |