High performance cold finger V2A large S-K100-Z

Type_S-K100
Type S-K100-Z
V2A-groß-sketch
מספר קטלוגי : KG S-K100

Gas cleaning by condensation/vacuum systems

Made of Stainless Steel 1.4301
Manufacturer: KGW - Isotherm

DESCRIPTION

High-performance cold finger V2A large S-K100-Z

Cold Trap, two Sections

A special version is the two-section cold trap. It has an ISO-K 100 flange as the connection part
This type of cold trap enables the condensation area to be separated from the upper section of the cold trap
This ensures that the removal of the condensation and the cleaning of the cold traps can be carried out very easily
This version is also suitable for when a cold trap has to be permanently installed inside an apparatus so that only the lower section of the cold trap has to be removed in order to empty out the condensation
The ISO-K 100 flange connecting piece is secured with 4 ISO-K-claw clamp stainless steel and this is included in our scope of delivery


Applications

gas cleaning by condensation e.g in vacuum systems

Cold Finger System

versions

KF NW25 = Small flange NW25
special dimensions
special connections

Advantages

baffles for optimized condensation
made of stainless steel 1.4301 (1.4404 on request)
good chemical resistance
good thermal resistance
simple low-cost design
quick exchange is possible
two sections



Cold traps / cold fingers

Hence different materials may be present in the gas stream (e.g., water/solvent/acid or alkali containing gases), the condensation temperature of the material to be condensed must be considered first. Having a cold trap, the material made off (glass or metal) and the geometry of the cold trap play an important role regarding the performance of the cold trap. In order to increase the performance of cold traps, these are sometimes provided with integrated baffles, so that the gas is more swirled in the condensation space and thus better condensation can take place on the cold inner wall of the cold trap

In general, it should be noted that the liquid used for cooling (LN2 or CO2) should be at least 50 ° C colder than the condensation temperature of the substance that you want to condensate out of the gas stream. If you would like to filter e.g. a solvent such as methanol (melting point -98 ° C) or acetone (melting point -95 ° C) out of a gas stream, you will need LN2 (about -196 ° C) as a coolant to achieve sufficient cooling capacity in the cold trap. For water, the melting point is 0 ° C which means that a mixture of CO2 and acetone (about -77 ° C) would be sufficient for water vapor

In order to obtain a constant performance of a cold trap / cold finger, the coolant level (LN2) inside the Dewar flask also must be kept constantly on a high level. This can be achieved with automatic LN2 level control. By such an automatic LN2 level controller, the cold trap / cold finger is always supplied with sufficient LN2 coolant, so that an optimal condensation performance of the cold trap / cold finger is guaranteed. For this purpose, complete LN2 level control systems for cold traps are offered


SPECIFICATIONS

Technical Data Cold finger S-K100-Z

TypeCondensate capacityCoolant capacityfor Dewar Typecold finger connectionsArt. No.
Cold finger S-K100-Z app. 1,5 l 16/18 l 33C / DSS-D250/450 KF NW 25 17154





Spare parts

Spare partsArticle-No.
Dewar made of glass Type 33C 1244
Dewar made of stainless steel Type DSS-D250/450 2407
Plastic ring for Type 33 17155
Plastic ring for Type DSS-D250/450 17156
CO2 wire bracket for Type 33C 17157
CO2 wire bracket for Type DSS-D250/450 17158
Claws for S-K100-Z 17159
Centering ring ISO-K100 17160